Skip to content

The open beta runs until 30 November. From 1 December Volter is paid, and accounts created before 1 December stay free until 31 December. See the prices

The distribution board

Build your distribution board with RCDs, circuit breakers and home automation modules, so Volter derives the circuits, the single-line diagram and the board layout from it.

What the distribution board does

In the Distribution board tab you rebuild the board as it hangs on the wall: rails with modules on them. Everything electrical starts from here:

  • Every circuit breaker is a circuit. So is every output of a home automation module.
  • The order on the rails sets the circuit letters: A, B, C.
  • Volter draws the single-line diagram from what is here.
  • On the plan, Assign circuit lets you choose from the circuits you make here. See Assigning circuits.

Creating the main board

If you open the Distribution board tab in a project without a board, the Set up main board window appears.

  1. Give the board a name under Name. It already says "Main board".
  2. Under Main RCD, fill in the values: Amperage, Short-circuit rating (kA), Fault current (mA) and RCD type. You pick a suggested value or type a number of your own.
  3. Volter fills in Poles itself. It follows the voltage of the project: 4P on a three-phase supply, otherwise 2P.
  4. If you want to add the cable from the meter, unfold Supply cable meter - main switch. See The supply cable.
  5. Click Create.

The board is now there, with the main RCD above the board.

If you closed the window with Cancel, it says "No board in this project yet". Click Add board to open the window again.

Adding modules

  1. Click Add module in an empty board, the plus sign at the end of a row, or Add row at the bottom for a new rail.
  2. Choose the kind of module:
    • RCD
    • Circuit breaker
    • Home automation module
    • Power supply
  3. The module goes to the end of that row and is selected right away. The panel with its details is open.

Main RCD is only in the list if the project does not have one yet.

A new circuit breaker gets the name "Circuit" with a number and starts as 16 A, 2P, curve B, on 2.5 mm². A new RCD is called "RCD" with a number and starts as 40 A, 2P, 30 mA, type A.

Need a module once more? Select it and click Duplicate module at the bottom of the panel. The copy is placed next to it, with the same values.

You add modules on the rail. In the Tree view you cannot create modules.

Setting the values

Click a module. In the panel you change its details. Name is always at the top.

Circuit breaker

  • The device: Amperage, Poles, Width (DIN), Short-circuit rating (kA) and Curve.
  • The cable of the circuit: Wire size (mm²), Number of conductors, With earth conductor, Cable type, CPR class, Cable location, In conduit and Number of cables.
  • Behind RCD: what the circuit breaker hangs behind. See What hangs behind what.
  • Diagram colour: the colour of the circuit on the plan and the diagram.

For an RCBO you tick With RCD (RCBO). Two fields are added: Fault current (mA), which starts at 30, and RCD type. On the single-line diagram it stays one device in its own place, with the fault current below it.

RCD and main RCD

Amperage, Poles, Short-circuit rating (kA), Fault current (mA) and RCD type. An RCD also has Width (DIN) and Parent. The main RCD carries the supply cable.

The main board needs a main RCD. That is why you cannot delete the last one.

Home automation module

  • Module type: Switching or Dimming.
  • Home automation controlled: turn this off for a classic switching or dimming module. It gets no home automation symbol.
  • Width (DIN): a number from 1 to 12.
  • Behind RCD/breaker: the circuit breaker the module hangs behind. Without that choice the module is not on the single-line diagram. If you choose an RCD, the AREI check reports that the module has no overcurrent protection.
  • Power supply: the power supply module that drives the home automation module. This field only shows for a home automation controlled module.
  • Outputs: click + Add output for every output and give it a name. Every output is a circuit, with the letter of the module and a number, such as D.1.

How to put push buttons and lights on those outputs is explained in Push buttons and home automation.

Power supply

A power supply has two fields: Behind RCD/breaker and Voltage. Hang the power supply behind a circuit breaker too. It gets no circuit letter, because no devices hang on it directly.

What hangs behind what

A new circuit breaker hangs directly behind the main RCD. Put it behind the right RCD yourself.

A circuit breaker behind an RCD

  1. Select the circuit breaker.
  2. Under Behind RCD, choose the RCD. None (main bus) hangs it directly behind the main RCD again.

An RCD behind another RCD

Select the RCD and choose under Parent what it hangs behind.

An RCD or circuit breaker behind a circuit breaker

Both lists have the Behind a circuit breaker group at the bottom. Choose a circuit breaker there, for example a general circuit breaker that protects a series of RCDs. That circuit breaker then feeds other modules and is no longer a circuit itself: it loses its letter and disappears from the Circuits list. If you remove everything behind it again, it becomes an ordinary circuit once more.

A circuit breaker is only in that group if nothing else hangs on it: no devices on the plan, no other board, no home automation module and no power supply.

Dragging in the tree

Choose Tree at the top. Drag a module onto an RCD or circuit breaker to hang it behind it. Drag it onto the main RCD or onto the name of the board to put it directly behind the main RCD. Places where the module may not hang do not accept it. Dragging to another board is not possible.

Dragging modules and rows

The place on the rail says nothing about what hangs behind what. It does set the circuit letters and what the board layout looks like.

  • Moving a module: drag it to another spot on its row, to another row, or to the empty rail at the bottom for a new row. While you drag you already see where it lands.
  • Leaving a free space: drop the module where you want it, also with room in between. The rail is divided into DIN units and a module stays where you put it. Where a module leaves or is deleted, a gap remains. The other modules only shift if they are in the way.
  • Moving a whole row: drag the handle with the six dots to the left of the rail up or down.

With your finger, you first hold a module for a moment. After that it follows your finger.

The main RCD sits above the board and cannot be dragged.

If circuit letters shift because of what you did, Volter reports it at the bottom, such as "Circuit letter C has moved". The labels on the plan and the diagram follow by themselves.

The DIN width

Volter draws every module as wide as it is in the board, in units of 18 mm. Width (DIN) says "Automatic" by default, with the width after it. The width then follows the poles:

1P2P3P4P
Circuit breaker1134
RCD and RCBO2244

If your device is different, choose a width from 1 to 8. Volter remembers that choice: from then on, every new circuit breaker or RCD with the same poles gets that width. Choose "Automatic" again to follow the poles once more.

A power supply is always 2 units wide. For a home automation module you type the width yourself.

Favourites

A circuit breaker or RCD that you place often can be saved with its values.

  1. Select the module and click the star at the bottom of the panel, Save as favourite.
  2. Give a name under Favourite name and click Save.
  3. From now on the favourite is under Favourites in the menu you use to add a module, in every project. One click places a module with those values.

If the star is filled, the module matches a favourite exactly. A click then opens that favourite in the settings.

You change, create or delete favourites through Manage favourites… at the bottom of that menu, or in Settings under Board favourites. There you also create one directly with New circuit breaker or New RCD. From eight favourites on, the menu has a search field.

A favourite saves the technical values. The name of the circuit, the colour and the RCD it hangs behind belong to the project and do not come along.

The supply cable

You fill in the cable from the meter to the main RCD when you create the main board, or later:

  1. Click the main RCD above the board.
  2. Under Supply cable meter - main switch, fill in what you know: Wire size (mm²), Number of conductors, With earth conductor, Cable type, CPR class, Cable location and In conduit.

Everything is optional. The cable only appears on the single-line diagram once you fill in the wire size and the number of conductors.

Adding an extra board

  1. In the row below the tabs, click the name of the board and choose Add board. The Add new board window opens.
  2. Give the board a name under Name, for example "Garage".
  3. Under Fed by, choose which circuit breaker feeds the board:
    • "New circuit breaker in", with the name of your main board: Volter puts a new circuit breaker in the main board.
    • An existing circuit breaker, if you have already drawn the supply. The list only holds circuit breakers that nothing hangs on yet.
  4. Below the list you see the tree of all boards, with the new board in its place. Click Create.

The circuit breaker that feeds the board stays a circuit with a letter. Do not put devices on it: the AREI check reports that, and they are not on the single-line diagram. On the rail, below its name, there is an arrow with the board it feeds. Its panel has Feeds board, with Go to board to jump to that board. There you also choose another board, or None to disconnect the supply. Above the sub-board it says "Fed from", with the board and the values of that circuit breaker.

Switching between boards: click the name of the board in the row below the tabs and choose another board. That picker is also on the single-line diagram, because every board has its own diagram.

Renaming or deleting: open the picker and click the three dots next to a board. Choose Rename or Delete. The circuit breaker that fed a deleted board stays.

The board code: the circuits of the main board are called A, B, C. On another board one character goes in front, such as G-A. Volter picks the first free letter from the name of the board. In the picker that code is in a small box in front of the name. Type another letter or a digit in it to change it.

Rail, Tree and Both

At the start of the row below the tabs you choose how you see the board:

  • Rail: the board with its rails. Here you add modules and drag them.
  • Tree: all boards below each other, with every module indented under the protection it hangs behind. Per circuit you see how many loads are on it. A 30 mA RCD shows how many circuits it counts, such as 5/8. Messages from the AREI check are next to the module they are about.
  • Both: the tree on the left and the rail on the right. This choice only shows if the window is wide enough. Drag the divider to make the tree wider or narrower.

If you click a module of another board in the tree, the rail jumps to that board. In Tree the board picker is not there, because the tree shows all boards.

The link with plan, diagram and PDF

  • Assign circuit: every circuit breaker and every output is in the Circuits list on the floor plan. If there are symbols without a circuit on the plan, Assign symbols in the row below the tabs shows how many. One click takes you to the plan.
  • Single-line diagram: Volter draws one diagram per board, in the order of the rails. What you change in the distribution board is there right away.
  • PDF: the Board layout part puts the rails of each board on a page, with circuit letter, amperage and name. See Export a PDF.

When a colleague has the project open

If someone in your team has the project open, a bar below the tabs says "Read only" with the name of your colleague. You can view the distribution board, switch boards and click a module to read its values. Whatever you change anyway jumps right back. Renaming a board does not work then either.

If you want to edit anyway, click Take over anyway. Your colleague then loses what was not saved yet.

Problems

I cannot find a main switch in the list

In Volter that is the Main RCD. It sits above the board and comes by itself when you create the main board. It is only in the list of modules if the project does not have one yet.

My circuit breaker is not under the RCD on the diagram

Sitting next to an RCD on the rail is not enough. Select the circuit breaker and choose the RCD under Behind RCD, or drag it onto the RCD in the Tree.

My circuit breaker has no letter any more

An RCD or circuit breaker hangs behind it. It then feeds other modules and is not a circuit itself. Look in the Tree at what hangs under it.

I cannot hang anything behind a circuit breaker

The circuit breaker is only in the Behind a circuit breaker group if it is free. First take the devices off its circuit, and disconnect a board, home automation module or power supply that it feeds.

The letters of my circuits have changed

The letters follow the rails from top to bottom and from left to right. After dragging, adding or deleting a circuit breaker or home automation module, they shift along. If that was not the intention, use Undo.

There is a gap on my rail

That is intended. Where a module leaves or is deleted, its place stays free. Drag the next module to the left to close the gap.

I cannot delete a module

  • The last main RCD always stays.
  • If the circuit breaker feeds another board, Volter first asks whether you want to disconnect the board.
  • If there are devices on the circuit, Volter asks for a confirmation. After deleting, they have no circuit.

I cannot delete a board

The last board cannot go. Neither can the board with the main RCD.

I do not see Both

The window is too narrow for the tree and the rail side by side. Make the window wider, or switch between Rail and Tree.

I cannot add a module in the tree

You add modules on the rail. Choose Rail or Both.

My home automation module shows as an error in the AREI check

Look at which message it says:

  • The module has no supply path: choose a circuit breaker under Behind RCD/breaker.
  • The module hangs directly behind an RCD: under Behind RCD/breaker, choose a circuit breaker instead of the RCD.
  • The module has no power supply module: add a Power supply on the rail and choose it in the panel of the home automation module under Power supply.

The supply cable is not on the single-line diagram

For the main RCD, fill in at least Wire size (mm²) and Number of conductors.

My changes jump back

A colleague has the project open and you are only looking along. See When a colleague has the project open.

Valid for Volter 1.3.0 · images from 11/20/2026