Connection box and junction box

Draw a connection box next to a fixed device or a junction box on your plan, and see where the number goes on the single-line diagram.

Two boxes, one symbol

You find them in the Symbols panel, in the Other group:

  • Connection box: the box a fixed device connects to, such as a hob.
  • Junction box: a box where the cable branches off.

You place them like any other symbol, see Placing symbols. The connection box and the junction box have the same symbol. The AREI only has one for both.

A connection box with a device

A connection box belongs to the device that connects to it. You say so with a connection:

  1. Place the connection box and the device, for example a hob.
  2. Choose Draw connection, or press T.
  3. Click the connection box and then the device.
  4. Give one of the two a circuit with Assign circuit. The other one gets the same circuit.

On the single-line diagram the box now sits in front of the device, on the same branch. The device carries the number, such as A2. The box gets no number of its own.

A connection box without a device

If nothing hangs on the box yet, for example a provision for a later device, you give the box itself a circuit. It then sits on its own branch and carries the number itself.

If you connect a device to it later, the number moves to the device.

The junction box

A junction box only shows where the box sits in the home. You do not give it a circuit. It is on the floor plan, not on the single-line diagram and not in the legend.

Boxes and the AREI check

A box is not a load. It does not count towards the limit of 8 socket outlets per circuit, not towards a mixed circuit and not towards the dedicated circuit of a device.

Problems

My connection box has no number

That is right if it is connected to a device: then the device carries the number. If it has no device and no number either, it has no circuit yet. Give it one with Assign circuit.

The box is on a different branch than the device

They are not connected yet. Draw a connection from the box to the device, see Connecting symbols.

My junction box is not on the single-line diagram

A junction box is only on the floor plan. If the box has to appear on the single-line diagram, use a connection box.